Home|Journals|Articles by Year|Audio Abstracts
 

Original Research

Med Arch. 2013; 67(4): 252-255


Diagnostic Accuracy of Sentinel Lymph Node Biopsy in Axillary Lymph Nodes at the Early Stages of Breast Cancer

Sadat Pusina.




Abstract

Introduction: For almost 100 years, standard procedure for evaluation of axillary lymph node status has been axillary nodes dissection (ALDN)–dissection of 1st, 2nd or possible 3rd level of axilla. Use of less invasive evaluation methods of axillary node pathologically (PH) status of non-invasive breast carcinoma has been started before about 30 year and that new method has been named sentinel lymph node biopsy (SLNB). Objective: Primary objective of study is to establish specificity, sensitivity, positive and negative predictive value of SLNB method comparing to presents of malignant changes of axillary sentinel lymph node and to establish true indication for ALDN. Patients: Study included 50 female patients, aged between 18-75, at Clinic for Glandular and Oncological Surgery, Clinical Center University of Sarajevo (CCUS), with non-invasive breast carcinoma, in the period from January 2008-January 2011, which fulfill established criteria. Material and methods: The study is of retrospective-prospective, clinical-manipulative and descriptive-analytic character. Sample consisted of patients of Clinic for Glandular and Oncological Surgery with diagnosed breast carcinoma, at T1 and T2 stage, with adequate preoperative preparation. Preoperative imaging with injection of radioactive isotope Tc99m albumin-colloid is done at the Clinic for Nuclear Medicine CCUS. Intraoperative PH examination of SLN node (or nodes) by frozen-section and hematoxylin-eosin staining and postoperative PH examination of lymph nodes after ALND was done at the Institute for Clinical Pathology and Cytology CCUS. Intraoperative identification of SLN is done with manual gamma probe. After the SLNB, all the patients underwent immediately appropriate breast carcinoma surgeries followed with dissection of 1st and 2nd level of axilla on the Clinic for oncology and glandular surgery of CCUS. Results: Statistic data evaluation was done by statistical program Med Calc for Windows, version 12.2.1.0 (MedCalc Software Mariakerke, Belgium). In the part of descriptive statistics all results are shown in table manner: mean, 95% CI for average value, standard deviation, median values, 95% CI for median value, maximal value, 25-75 percentiles, evaluation of normal distribution by D’Agostino-Pearson test, Chi square test for evaluation of differences in frequencies between subgroups. For evaluations of specificity and sensitivity of results were applied 2x2 tables and following equations: sensitivity=TP/TP+LN, specificity=TN/P+TN, overall accuracy = TP+TN/N, positive predictive value= TP/TP+LP, negative predictive value = TN/LN+TN. Defined significance level was p

Key words: breast carcinoma, radioactive isotope, sentinel lymph node biopsy






Full-text options


Share this Article


Online Article Submission
• ejmanager.com




ejPort - eJManager.com
Refer & Earn
JournalList
About BiblioMed
License Information
Terms & Conditions
Privacy Policy
Contact Us

The articles in Bibliomed are open access articles licensed under Creative Commons Attribution 4.0 International License (CC BY), which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.