Original Article



Evaluating the dıagnostıc accuracy of birads assessment of mammography and ultrasound according to ultrasound-guıded core needle biopsy: 9 years-experience in a small town

Sukruye Firuze Ocak Karatas, Murat Beyhan, Erkan Gokce.




Abstract
Cited by 0 Articles

Aim: To examine the diagnostic accuracy of the BI-RADS (Breast Imaging Reporting and Data System) assessment of ultrasonography and/or mammography according to US-guided core needle biopsy.
Materials and Methods: 463 patients who had ultrasonography and/or mammography imaging and subsequent US-guided core needle biopsy between June 2011 and June 2020 in the Radiology Departments of two different centers in our town were studied retrospectively. BI-RADS assessment of ultrasonography and/or mammography were compared with histopathological diagnoses. When both examination existed, the higher score was determined as the final BIRADS category.
The diagnostic efficiency of ultrasonography and/or mammography for determining malignancy were calculated.
Results: Of the 463 lesions 222 (47.9%) were malignant and 241(52.1%) were benign. Based on ultrasonographic examination, malignancy was observed in 5 of the 86 (5.8%), 89 of 178 (50%), 4 of 63 (6.3%), 26 of 26 (100%) and 86 of 86 (100%), cases reported as BI-RADS 3, 4, 4A, 4C and 5. Based on mammography results, all of 50 masses (100%) classified as BI-RADS 5 and 38 of 47 masses (80.8%) classified as BI-RADS 4 were malignant. The frequency of malignancy in BI-RADS 3 masses was 5.8% based on ultrasonographic examination and 0.7% with both modalities.
Sensitivity, specificity, positive predictive value, negative predictive value and diagnostic accuracy for ultrasonography were 92.2, 61.0, 69.1, 89.2, and 76.2%; for mammography were 96.7, 41.1, 89.8, 70.0, and 88.0%; for combined radiological evaluation were 99.5, 53.5, 66.3, 99.2 and 75.5% respectively.
Conclusion: When mammography and ultrasonography were evaluated together, the rate of malignancy in BIRADS 3 lesions decreased from 5.8% (only ultrasonography) to 0.7%. In addition, sensitivity and negative predictive value increased statistically significantly (p

Key words: BI-RADS; breast; mammography; ultrasonography; US-guided core needle biopsy






Full-text options


Share this Article


Online Article Submission
• ejmanager.com




ejPort - eJManager.com
Refer & Earn
JournalList
About BiblioMed
License Information
Terms & Conditions
Privacy Policy
Contact Us

The articles in Bibliomed are open access articles licensed under Creative Commons Attribution 4.0 International License (CC BY), which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.