SOUND ABSORPTION FOR CONCRETE CONTAINING POLYETHYLENE TEREPHTHALATE WASTE

Tam Kai Loong, Shahiron Shahidan, Adib Fikri Abdul Manaf, Faisal Sheikh Khalid, Sharifah Salwa Mohd Zuki, Mustaqqim Abd Rahim, Mohd Haziman Wan Ibrahim, Suraya Hani Adnan, Mustafa Juma A. Mijarsh, Mohamad Azim Mohammad Azmi.

Abstract
Plastic solid waste generation increases every year with the current consumption habit prevalent in society nowadays. The improper disposal of plastic has been a major concern to the environment as it is not easily degradable. The issue of environmental pollution caused by polyethene terephthalates (PET) has been extensively discussed and the best solution proposed is recycling. Fibre Concrete (FC) was a composite material resulting from the addition of fibres to ordinary concrete. The objective of this research was to determine the acoustic absorption coefficient of concrete containing 0%, 0.5%, 1.0%, 1.5%, 2.0% of PET fibre compared to normal concrete. In this study, straight and irregular recycled PET fibres were used. The fibres were simply cut from PET plastic bottles. The length and width of recycling PET fibre were fixed at 25 mm and 5 mm respectively. The chosen percentages were 0.5%, 1.0%, 1.5% and 2.0% of fiber. A water-cement ratio of 0.45 was acceptable for all ranges. The tests that were conduct include the slump test, compression test, and impedance tube test. The specimens were tested on day 7 and day 28 after the concrete is mixed. The end of this research results for the compressive strength of normal concrete after 28 days of curing was 48.2 MPa while concrete with 0.5% PET, 1.0 % PET, 1.5% PET and 2.0% PET recorded a compressive strength of 50.9 MPa, 49.8 MPa, 47.9 MPa and 46.6 MPa respectively. The result of the impedance test received at age 28 days was 0.13 for normal concrete and 0.16, 0.14, 0.16 MPa, and 0.14 for 0.5% PET, 1.0 % PET, 1.5% PET and 2.0% PET respectively. In conclusion, the aspect ratio of the fibres to the concrete must be correlated to avoid reducing durability. In conclusion, the addition of 0.5% PET recycled fibre into concrete showed the best value in terms of strength and 0.16 for the sound absorption coefficient.

Key words: PET fibre concrete, sound absorption, impedance tube test


Full-text options

Full-text Article




Advertisement
American Journal of Diagnostic Imaging

SUBMIT YOUR ARTICLE NOW




ScopeMed.com
BiblioMed Home
Follow ScopeMed on Twitter
Author Tools
eJPort Journal Hosting
About BiblioMed
License Information
Terms & Conditions
Privacy Policy
Contact Us

The articles in Bibliomed are open access articles licensed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International License (https://creativecommons.org/licenses/by-nc-sa/4.0/) which permits unrestricted, non-commercial use, distribution and reproduction in any medium, provided the work is properly cited.
ScopeMed is a Database Service for Scientific Publications. Copyright ScopeMed Information Services.