Research Article

EEO. 2021; 20(3): 3383-3390


Effect Of Unglazed Solar Flat Plate Collector On Thermal Efficiency And Outlet Temperature

Abhishek Rohatagi, Digvijay Singh, Paras Chauhan, Akashdeep Negi, Rajesh P. Verma, R. Dobriyal, D.B. Singh, Ms Priya Arundhati.




Abstract

The Present research article deals with the experimental investigation of an unglazed flat plate collector for the climatic condition of Dehradun, Uttarakhand, India. In the present study water is used as the working fluid, and the mass flow rate and temperature of inlet water was kept fixed at 0.0051kg/sec and 32˚C from the preliminary investigation. The experiment was carried out for two consecutive days and the outlet temperature of the unglazed flat plate collector was found to be 36˚C and 37˚C with the instantaneous efficiency of 11.11% and 13.79% for with the maximum solar intensity of 1140W/m2 and 1145W/m2 respectively for the day 1 and 2. The study shows without glazing material the outlet temperature was directly proportional to the solar intensity also the maximum heat gain during experimentation was found for day 2.

Key words: Unglazed Flat Plate Collector, Instantaneous Efficiency, Heat Gain, Mass Flow Rate.






Full-text options


Share this Article


Online Article Submission
• ejmanager.com




ejPort - eJManager.com
Refer & Earn
JournalList
About BiblioMed
License Information
Terms & Conditions
Privacy Policy
Contact Us

The articles in Bibliomed are open access articles licensed under Creative Commons Attribution 4.0 International License (CC BY), which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.