Home|Journals|Articles by Year|Audio Abstracts
 

Original Research

Med Arch. 2011; 65(4): 216-220


Assessment of Depth of Anesthesia: prst Score Versus Bispectral Index

Jasmina Smajic, Mirsada praso, Mirsad Hodzic, Samir Hodzic, Amna Srabovic-Okanovic, Nedim Smajic, Zinka Djonlagic.




Abstract

Assessment of depth of anesthesia is the basis in anesthesiologist’s work because the occurrence of awareness during general anesthesia is important due to stress, which is caused in the patient at that moment, and due to complications that may arise later. There are subjective and objective methods used to estimate the depth of anesthesia. The aim of this study was to assess the depth of anesthesia based on clinical parameters and on the basis bispectral index, and determine the part of bispectral monitoring in support to clinical assessment. Material and methods: Sixty patients divided into two groups were analyzed in a prospective study. In first group (group 1), the depth of anesthesia was assessed by PRST score, and in the second group (group 2) was assessed by bispectral monitoring with determination PRST score concurrently. In both groups PRST score was assessed in four periods, while bispectral monitoring is used continuously. For analysis were used the BIS index values from the equivalent periods as PRST scores. PRST score value 0-3, and BIS index 40-60 were considered as adequate depth of anesthesia. The results showed that in our study were not waking patients during the surgery. In the group where the depth of anesthesia assessed clinically, we had a few of respondents (13%) for whom at some point were present indicators of light anesthesia. Postoperative interview excluded the possibility of intraoperative awareness. In the second group of patients and objective and clinical assessment indicated at all times to adequate depth of anesthesia. Conclusion: The use of BIS monitoring with clinical assessment allows anesthesiologists precise decision-making in balancing and dosage of anesthetics and other drugs, as well as treatment in certain situations.

Key words: depth of anesthesia, PRST score, bispectral index






Full-text options


Share this Article


Online Article Submission
• ejmanager.com




ejPort - eJManager.com
Refer & Earn
JournalList
About BiblioMed
License Information
Terms & Conditions
Privacy Policy
Contact Us

The articles in Bibliomed are open access articles licensed under Creative Commons Attribution 4.0 International License (CC BY), which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.