Case Report



Tecnics Eyhance Iol as a Solution for Anisometropic Amblyopia Cataract Patient: a Case Report

Mirnesa Odobasic, Alma Biscevic,, Melisa Ahmedbegovic-Pjano, Ajla Skopljak-Salkica, Bojana Pandurevic.




Abstract

Background: Amblyopia affects 1-3% of the population, leading to irreversible vision loss in children and adults. Treatment options include refractive correction, occlusion therapy, and atropine penalization. Anisometropic amblyopia, caused by a difference in refractive status between the eyes, can be treated using contact lenses, glasses, ICL implantation, or cataract surgery with intraocular lens implantation. Tecnis Eyhance IOL is a superior solution, improving vision after eye surgery with a low incidence of halo, glare, or starburst. Objective: The aim is to present the case of a patient with anisometropic amblyopia, in whom Eyhance IOL was implanted in both eyes as a solution to refractive error and initial cataract due to intolerance for contact lenses. Case report: A 58-year-old female patient presented to our clinic complaining of blurry vision in her left eye that had persisted for a year. The patient reported intolerance to contact lenses and a history of amblyopia in her right eye. CDVA was 0.20 with -9.00/-1.50 x 25◦ in her right and 0.80 with +4.00 sphere correction in her left eye, while her CNVA was J9 with +2.50 and J1 with +2.50. Slit-lamp examination revealed early cataracts in both eyes, with otherwise normal findings. A dilated fundus examination showed vitreous liquefaction and myopic macula in the right eye but normal results in both eyes‘ posterior segments. The IOP was within normal limits, and the eye‘s axial length was measured. Considering the patient‘s intolerance to contact lenses, cataract surgery with intraocular lens implantation was deemed appropriate. Given the anisometropic amblyopia, the Eyhance lens was selected to optimize the patient‘s visual acuity. Following the procedure, the patient‘s visual acuity improved significantly, with her best CDVA at 0.35 in the right eye and 0.95 in the left eye. With +1.50 sphere correction, the CNVA was also enhanced, with the patient reading at J4 and J1 for her right and left eye, respectively. These improvements may have positively impacted the patient‘s quality of life and ability to perform daily activities. Conclusion: Anisometropic amblyopia in 58-year-old women was treated successfully with cataract surgery and implantation of Eyhance IOL.

Key words: anisometropia, amblyopia, cataract surgery, Technics Eyhance IOL






Full-text options


Share this Article


Online Article Submission
• ejmanager.com




ejPort - eJManager.com
Refer & Earn
JournalList
About BiblioMed
License Information
Terms & Conditions
Privacy Policy
Contact Us

The articles in Bibliomed are open access articles licensed under Creative Commons Attribution 4.0 International License (CC BY), which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.